ECO-5 / 6100 Identified Problems
Pump Does Not Work!
If pump 1 does not operate, perform the following tests to correct the problem:
·
Check to see if there is an error
message on the spaside control. If this
is the case, go to the specific section
that refers to that message.
·
Verify that jumper #2 is set properly for
single or dual speed operation.
·
Check spaside control to see if the
Pump Indicator is illuminated when the
pump key is depressed.
Pump Indicator
does not illuminate
·
If the Pump Indicator is not illuminating,
use your spare spaside control to verify
that the keypad is not defective. If the
keypad is defective, replace the spaside
control. If the keypad is not defective,
replace the printed circuit board.
Pump Indicator
does illuminate
·
If the Pump indicator illuminates on the
Spaside control when the pump key is
pressed, verify that Pump works in one
of the speeds.
·
If the Pump works in one of two speeds,
read the voltage at the system board for
both speeds.
·
Turn Pump onto high speed and
measure the voltage between the white
wire (P12) and the red wire (P6).
Voltage reading should be 120 VAC.
·
Turn Pump to Low speed and measure
the voltage between the white wire
(P12) and the black wire (P9). Voltage
reading should be 120 VAC.
·
If the voltage measurements are good,
replace the Pump. If not, replace
system circuit board.
P12
P6
P12
P9