ECO-5 / 6100 Identified Problems
Ozonator Does Not Work!
If the Ozonator does not work, perform the following tests to correct the problem:
·
Note: The ozonator has a constant
power supply. It does not run only
during filtration cycles.
·
Take a voltage measurement at the
Ozone white wire (P12) and the black
wire (P15). If no voltage is present,
check the 30 amp inline fuse for
continuity. Replace the fuse if it is found
to be bad. Voltage reading should be
120 VAC.
·
If the voltage measurements are good,
replace the Ozonator.
ECO-5 / 6100 Identified Problems
Spa Light Does Not Work!
If the spa light does not work, perform the following tests to correct the problem:
·
It is important to measure voltage when
the light is connected to the System.
Power must remain on.
·
The first step is to replace the bulb of
the spa light.
·
If the Light does not come on, use your
spare spaside control to verify that the
keypad is not defective. If it is, replace
the spaside control.
·
If the Light is still not coming on, open
the access panel on the control box and
measure the voltage between the two
wires of the light connector on the
printed circuit board at P7 & P11.
Voltage reading should be 120 VAC.
·
If the voltage reading at the printed
circuit board is correct, ensure that
there is 12 VAC present at the light
socket. If you do not get a good voltage
reading, replace the printed circuit
board.