ECO-5 / 6100 Identified Problems
Nothing Works!
If everything is connected properly and nothing seems to work, there is probably a problem with the power supply.
If
you detect Low or High voltage conditions at the input power connection contact an electrician.
Perform the following tests to identify and correct the problem:
120V Operation
·
Measure the input voltage between Line
1 (P8) and Neutral (P10). You should
read approximately 120 VAC. (if you do
not get a good voltage reading, check to
make sure the system rocker switch is
in the ON position and that the Line 1
fuse is good.)
·
If you are getting good voltage readings
but nothing seems to work, verify that
the Spaside control is properly
connected to the system circuit board
(and external receptacle, if applicable).
If nothing works, replace the circuit
board.
ECO-5 / 6100 Identified Problems
Spa Is Not Heating!
If the spa seems to not be heating the water, perform the following tests to correct the problem:
·
Check the Spaside control for an error
message. If this is the case, go to the
specific section that refers to that
message.
·
Verify that there is a call for heat when
the Set Temperature is increased.
Press and hold the Up Arrow Key to
increase the temperature set point.
·
Verify that the Heater On indicator on
the spaside control is illuminated.