ECO-5 / 6100    Error Messages 

 

 

High Limit Sensor / Over Heat 

 

If the temperature of the water is at or higher than 115

°

F and the display on the Spaside control IS the right 

temperature, perform the following tests.

 

 

If the weather is 

very warm: 

· 

Remove the spa cover. Wait until the 

spa cools down (Add cold-water if 
necessary). 

 

 

If the weather is not 
a factor: 

· 

Lower the Set Temperature below the 
actual temperature of the water (The 
Heater On indicator on the spaside 
control should turn Off). 

· 

Open the access panel on the control 
box. With a voltmeter, read the voltage 
between P10 and P17 on the printed 
circuit board. This is the power supply 
for the heater relay coil. 

If you do not 

read 120 VAC

, the pump may be 

overheating the water during the 
filtration cycle. Lower the filter cycle 
duration. 

 
 

 

 

To Lower the Filter 
Cycle 

· 

Press both the Light and Up Arrow Key. 
The current duration will be displayed. 

· 

Use the Down Arrow Key to lower the 
value. (60, 120 or 180) 

· 

When the desired value is displayed, 
press both Light and Up Arrow Keys 
again to save the new setting. 

Note: If no key is depressed within 5 
seconds, the system will revert back to the 
normal mode of operation.   
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

  

 

 

 

 

 

P10 

P17 

Summary of Contents for Baja Sportub ECO-5/6100 Series

Page 1: ......

Page 2: ...1...

Page 3: ...uired Parts Required Error Messages FLO Message FLC Message Prr Message HL Message Programming Low Level Programming Identified Problems Nothing Works Spa Is Not Heating Pump Does Not Work Ozonator Do...

Page 4: ...cable Multi meter and clamp on Ammeter Accurate thermometer GFCI tester optional Parts Required Spaside control Temperature sensor Hi Limit sensor 30A Fuse System Board Pre Test Prior to the service c...

Page 5: ...switch A system with a pressure switch displaying the pressure or flow switch not activated message will not be corrected by replacing the pressure switch Verify that the pump is working If the pump i...

Page 6: ...r flow switch Pressure Switch Adjustment Important Test Fill spa to maximum water level Apply power and operate jets on high speed to establish full water flow throughout the system Turn OFF all power...

Page 7: ...e the probe in the spa water If this solved the problem replace the sensor Replace the printed circuit board if the problem has not been corrected ECO 5 6100 Error Messages High Limit Sensor Over Heat...

Page 8: ...f Open the access panel on the control box With a voltmeter read the voltage between P10 and P17 on the printed circuit board This is the power supply for the heater relay coil If you do not read 120...

Page 9: ...mming Low Level Programming It is possible to change the parameters of the Equipment System by positioning specific jumpers located on the system board Jumper 1 Position 1 High Current 240vac There is...

Page 10: ...the Line 1 fuse is good If you are getting good voltage readings but nothing seems to work verify that the Spaside control is properly connected to the system circuit board and external receptacle if...

Page 11: ...heating replace the printed circuit board If the Heater On indicator does illuminate Open the access panel on the control box and measure the voltage between P10 and P17 at the system circuit board Re...

Page 12: ...he keypad is not defective If the keypad is defective replace the spaside control If the keypad is not defective replace the printed circuit board Pump Indicator does illuminate If the Pump indicator...

Page 13: ...es not work perform the following tests to correct the problem It is important to measure voltage when the light is connected to the System Power must remain on The first step is to replace the bulb o...

Page 14: ...the following tests to correct the problem Make sure the Programming Jumpers are set properly Refer to Programming Replace spaside control with a spare Check to see if the keys are responding If they...

Reviews: