8
ECO-5 / 6100 Error Messages
High Limit Sensor / Over Heat
If the temperature of the water is at or higher than 115
°
F and the display on the spaside control DOES NOT show the
right temperature, perform the following tests.
·
Verify that the temperature sensor is
inserted properly and that cold air
cannot affect its readings.
·
Use foam to insulate the sensor from
cold air if it is the source of the problem.
·
Verify that the temperature sensor is
properly connected to the system
board. If it is, replace the sensor.
·
Replace the printed circuit board if the
error message still appears on the
display and the LED error indicator
remains illuminated.
ECO-5 / 6100 Programming
Low Level Programming
It is possible to change the parameters of the Equipment System by positioning specific jumpers located on the
system board.
Jumper 1
Position 1:
(High Current – 240vac): There is no current restriction. This allows the
heater to operate with the pump in high speed.
(Current Limiting)
Position 2:
(Low Current – 120vac): The system will not turn the heater on when the
pump is in high speed. The heater indicator will flash on the Spaside to tell
the user that there is a call for heat but the heater is not allowed to start.
Jumper 2
Position 1:
Two Speed Pump
(1 or 2 Speed Pump )
Position 2:
Single Speed Pump
Jumper 3
Position 1:
60 minutes Duration, Once a Day
(Filter Cycle Default
Setting)
Position 2:
180 minutes Duration, Twice a Day
Fahrenheit / Celsius
Press and hold the Light Key on the spaside control for 5 seconds to switch temperature
modes.