Phantom Dimmable
The following applies only to Phantom Dimmable models:
Operation
:
1. When starting a cool lamp, the ballast will apply 100% power for
15 minutes to properly heat the gasses in the lamp. The dimming
feature will not operate during this initial start-up period, but you
can preset the dimming ratio during this time without impacting
the warm up. After the warm up is complete, the ballast will run at
the set dimming ratio.
2. Press the dimming button to cycle through the dimming levels.
The appropriate LED indicator will light up to indicate selected
dimming level (100%-75%-60%).
3. In the event of an input power failure, check your power
connection, and then reset the ballast per the directions on page 5.
Warning
: If the ballast does not work after the reset, please return
it to the place of purchase.
4. Please check the output connection or replace the bulb in the
event of an output failure. If the ballast continues to fault after
precautions are taken, please return it to the place of purchase.
5. The Phantom line of ballasts has built in hot-restrike programming
to protect the lamp and ballast in the event of the ballast turning off
unexpectedly. The ballast will not attempt to restart a hot lamp for at
least 15 minutes. If your lamp fails to start immediately, DO NOT
cycle the power on and off. This can damage the lamp and ballast. If
after 1/2 hour your lamp is still not lit, shut off power to the ballast,
and reconnect. This will begin the startup sequence again.
Dimming switch
alternates ballast
output
LEDs indicate
operation status and
power level setting
6