Phantom Dimmable

The following applies only to Phantom Dimmable models:

Operation

:

1.   When starting a cool lamp, the ballast will apply 100% power for 

15 minutes to properly heat the gasses in the lamp. The dimming 

feature will not operate during this initial start-up period, but you 

can preset the dimming ratio during this time without impacting 

the warm up. After the warm up is complete, the ballast will run at 

the set dimming ratio.

2.  Press the dimming button to cycle through the dimming levels. 

The appropriate LED indicator will light up to indicate selected 

dimming level (100%-75%-60%).

3.    In the event of an input power failure, check your power 

connection, and then reset the ballast per the directions on page 5. 

     

Warning

: If the ballast does not work after the reset, please return 

it to the place of purchase.

4.  Please check the output connection or replace the bulb in the 

event of an output failure. If the ballast continues to fault after 

precautions are taken, please return it to the place of purchase.

5.  The Phantom line of ballasts has built in hot-restrike programming 

to protect the lamp and ballast in the event of the ballast turning off 

unexpectedly. The ballast will not attempt to restart a hot lamp for at 

least 15 minutes. If your lamp fails to start immediately, DO NOT 

cycle the power on and off. This can damage the lamp and ballast. If 

after 1/2 hour your lamp is still not lit, shut off power to the ballast, 
and reconnect. This will begin the startup sequence again.

Dimming switch 

alternates ballast 

output

LEDs indicate 

operation status and 

power level setting

6

Summary of Contents for Phantom PHE1THD

Page 1: ...INSTRUCTION MANUAL DIGITAL BALLASTS Power and Versatility Use horizontally vertically or mounted on the wall ...

Page 2: ...that should be fol lowed during the installation and maintenance of the product Please read it thoroughly before installing and operating this product 1 This digital ballast is designed specifically for HPS MH lamp operation 2 This ballast is for indoor use only Avoid exposure to excessive heat or contact with liquids 3 This ballast does not rely on the luminance enclosure for protec tion against ...

Page 3: ... 2 7 240v 4 2 120v 2 1 240v 3 2 120v 1 6 240v 0 98 100 275 4 0 kV 8 1 414 1 6 40 104 70 158 PHE400 120 240 424 3 7 N A N A N A 0 98 100 275 4 0 kV 8 1 414 1 6 40 104 70 158 PHE250 120 240 265 2 3 N A N A N A 0 98 100 275 4 0 kV 8 1 414 1 6 40 104 70 158 Performance see back page for definition of terms About your ballast 3 DIMMABLE DUAL VOLTAGE PHE1THD PHE600D LED status panel Reset Buttons Input ...

Page 4: ...ndle to center for wall mounting Fig C then retighten screws Installing and connecting the ballast 1 Find a suitable location for the ballast with sufficient cooling and away from any heat source We recommend vertical mounting 2 Before plugging your ballast in make sure it is disconnected from the power source the lamp is firmly installed into the lamp socket and the Lock Seal lamp cord is securel...

Page 5: ...ons work based on input power For 120v only one reset will trip if there s an issue for 240v both may trip The reset buttons also work as thermal cutoffs and may trip in case of an overheating situation After a reset button trips wait 15 minutes before pressing the reset button If after resetting the ballast the problem continues please contact your retailer for repair or replacement instructions ...

Page 6: ...the directions on page 5 Warning If the ballast does not work after the reset please return it to the place of purchase 4 Please check the output connection or replace the bulb in the event of an output failure If the ballast continues to fault after precautions are taken please return it to the place of purchase 5 The Phantom line of ballasts has built in hot restrike programming to protect the l...

Page 7: ...uit The higher the number the more stress is applied to internal parts the lamp and the power grid Gener ally a number below 10 is considered desirable in an electronic ballast application CF Crest Factor A measurement of how clean the ballast power output wave is A perfectly clean output sine wave would have a CF of 1 414 Given that some harmonics must exist in an electrical system the crest fact...

Page 8: ... covered under this warranty Hydrofarm will at our discretion repair or replace the ballast covered under this warranty if it is returned to the original place of purchase To request warranty service please return the ballast with original sales receipt to your place of pur chase The purchase date is based on your original sales receipt Hydrofarm Inc 2249 S McDowell Blvd Petaluma CA 94954 www hydr...