on reflective materials

H

ydrofarm warrants the Phantom Ballast to be free from 
defects in materials and workmanship. The warranty term 

is 3 years full/2 years prorated beginning on the date of purchase. 
Misuse, abuse, or failure to follow instructions are not covered 
under this warranty. Hydrofarm will, at our discretion, repair or 
replace the ballast covered under this warranty if it is returned to 
the original place of purchase. To request warranty service, please 
return the ballast, with original sales receipt, to your place of pur-
chase. The purchase date is based on your original sales receipt.

Hydrofarm Inc.

2249 S. McDowell Blvd., Petaluma, CA 94954

www.hydrofarm.com

WARRANTY

3 Years Full/2 Years Prorated

v2-2.2.2010

Summary of Contents for Phantom PHE1THD

Page 1: ...INSTRUCTION MANUAL DIGITAL BALLASTS Power and Versatility Use horizontally vertically or mounted on the wall ...

Page 2: ...that should be fol lowed during the installation and maintenance of the product Please read it thoroughly before installing and operating this product 1 This digital ballast is designed specifically for HPS MH lamp operation 2 This ballast is for indoor use only Avoid exposure to excessive heat or contact with liquids 3 This ballast does not rely on the luminance enclosure for protec tion against ...

Page 3: ... 2 7 240v 4 2 120v 2 1 240v 3 2 120v 1 6 240v 0 98 100 275 4 0 kV 8 1 414 1 6 40 104 70 158 PHE400 120 240 424 3 7 N A N A N A 0 98 100 275 4 0 kV 8 1 414 1 6 40 104 70 158 PHE250 120 240 265 2 3 N A N A N A 0 98 100 275 4 0 kV 8 1 414 1 6 40 104 70 158 Performance see back page for definition of terms About your ballast 3 DIMMABLE DUAL VOLTAGE PHE1THD PHE600D LED status panel Reset Buttons Input ...

Page 4: ...ndle to center for wall mounting Fig C then retighten screws Installing and connecting the ballast 1 Find a suitable location for the ballast with sufficient cooling and away from any heat source We recommend vertical mounting 2 Before plugging your ballast in make sure it is disconnected from the power source the lamp is firmly installed into the lamp socket and the Lock Seal lamp cord is securel...

Page 5: ...ons work based on input power For 120v only one reset will trip if there s an issue for 240v both may trip The reset buttons also work as thermal cutoffs and may trip in case of an overheating situation After a reset button trips wait 15 minutes before pressing the reset button If after resetting the ballast the problem continues please contact your retailer for repair or replacement instructions ...

Page 6: ...the directions on page 5 Warning If the ballast does not work after the reset please return it to the place of purchase 4 Please check the output connection or replace the bulb in the event of an output failure If the ballast continues to fault after precautions are taken please return it to the place of purchase 5 The Phantom line of ballasts has built in hot restrike programming to protect the l...

Page 7: ...uit The higher the number the more stress is applied to internal parts the lamp and the power grid Gener ally a number below 10 is considered desirable in an electronic ballast application CF Crest Factor A measurement of how clean the ballast power output wave is A perfectly clean output sine wave would have a CF of 1 414 Given that some harmonics must exist in an electrical system the crest fact...

Page 8: ... covered under this warranty Hydrofarm will at our discretion repair or replace the ballast covered under this warranty if it is returned to the original place of purchase To request warranty service please return the ballast with original sales receipt to your place of pur chase The purchase date is based on your original sales receipt Hydrofarm Inc 2249 S McDowell Blvd Petaluma CA 94954 www hydr...