In normal mode the unit will show the home screen detailing which formula has been selected. If the user has navigated
to any other part of the menu then after 5 minutes the unit will revert back to the home screen. Once a particular
formula has finished the unit will then revert back to Formula 1 (see alternative options in 6.5.7.2).
6.4.2.
In relay mode the home screen will just say
‘RELAY’
and only show the functionality that has been enabled in the ‘Edit
settings’ screen.
Note:
It is advisable to refer to the menu structure as detailed on pages 20 & 21.
6.4.3.
Maintenance mode
(Firmware version V2.09 onwards): The EvoClean now includes a ‘maintenance mode’ that can be navigated to from
the home screen (as per above).
When maintenance mode is activated the LED on the unit and RFS will flash and ‘maintenance mode’ will be displayed
on screen. When activated the unit will not accept any trigger signals, it will also not operate any solenoids or any other
functions. Maintenance mode will remain active until deactivated by the user.
Note:
When in maintenance mode the unit remains powered throughout. No covers should be removed. Unit must be electrically
isolated before covers are removed.
To begin setting up the EvoClean the installer needs to
navigate to:
Enter setup > Enter passcode (Default = 1234) and the
following screens will then be accessible.
The interface has been designed to allow simple and intuitive
programming. It is recommended that the unit is setup in the
following order.
User Screens?
Back
i
h
Yes
Machine Size
Back
i
h
Set
Operational Mode
Back
i
h
Set
Edit Products?
Back
i
h
Yes
Edit Formulas?
Back
i
h
Yes
Edit Settings?
Back
i
h
Yes
Set Date/Time?
Back
i
h
Yes
6.5. Setup & Programming Step 1: Program Controller
6.5.1.
User Screens
- Under user screens, the installer has the functionality to prime the individual chemicals during setup
and also view and reset the wash counts per formula.
6.5.2.
Machine Size
– This is set to the size of the washer extractor being installed. This can be set from 1 – 200kg. All
chemical delivery settings refer to this figure when calculating the amount of chemical to be injected during a formula.
6.5.3.
Operational
Mode
– As detailed in section 6.1.