Mist-n-Go User Manual
www.HydromistUSA.com
22
Question
Reasoning
Actions
What are
the
guidelines
for oil
changes?
1.
The highest and the lowest
operating temperatures will
directly affect the viscosity
and lubricity of oil.
2.
In harsh work environments
(e.g., excess heat, air
pollutants, direct exposure
to sunlight or rain, dust,
high humidity, bad air
quality), the selection of oil
and time between oil
changes will directly affect
the longevity of the
machine.
—
1.1 Please select an oil with
adequate viscosity for your
operating environment.
—
2.1 The oil change interval is
based on regular operation. The
operator should consider the
operating conditions in
determining intervals and should
shorten the interval depending on
the observed condition of the oil
(smell, color, viscosity,
composition).
1.
If the operator uses the
machine under constant
overpressure, it will lead to
the rapid loss of oil
lubricity.
2.
If the machine is left
unused for a long time or
only used rarely the oil will
deteriorate by oxidation or
cause internal component
degradation (with possible
internal rusting).
—
1.1 If consistently operating in an
overpressure condition, then the
oil change interval should be
shortened.
※
The performance of machine is
limited. Operation in overpressure
conditions will lead to component
damage and reduce the life span.
Follow the configuration
recommendations to increase
pump lifetime.
—
2.1 Change the oil before use if
the machine remains unused for
long periods of time (more than
one year without operation).
—
2.2 If the machine needs to be run
after a long period without use,
check the condition of the oil first.
—
2.3 If the components are visibly
rusted, the pump may need to be
replaced. Run the pump briefly
every 6 months to lubricate all
internal components.
Summary of Contents for F10-04-009
Page 1: ...Misting Pump User Manual ...