Mist-n-Go User Manual
www.HydromistUSA.com
9
4.3.12
The number of nozzles for the best misting effect will vary
depending on the pump used. If a lower number of nozzles than
recommended is used, the system will be over pressurized, if too
many nozzles are used, the pressure will drop and the
atomization effect will be poor. Please refer to catalog
specifications for details.
4.3.13
A valve installed in the end of misting system is recommended. It
will help to easily purge air from the system, especially in
extensively long installations, or with configurations where air is
easily trapped in the misting lines.
4.3.14
When misting, check all nozzles and ensure none are blocked. If
blocked, clean or change the nozzle.
4.3.15
When misting, check that all connectors are without leaks. If
there is leak, reinstall the connector or change it.
4.3.16
For storage during winter months, or where the pump will not be
used for an extended period of time, discharge the system
pressure and drain any standing water from the misting system.
Summary of Contents for F10-04-009
Page 1: ...Misting Pump User Manual ...