Mist-n-Go User Manual
www.HydromistUSA.com
8
4.3
Cautions
4.3.1
Do not operate the machine in temperatures below freezing
(0°C/32°F).
4.3.2
Before use, check for oil inside the pump. If there has been any
leakage, fill the oil.
4.3.3
Only use a power source with correct electrical voltage (V),
frequency (Hz) and current rating according to the machine
specifications.
4.3.4
Do not set up the operating pressure of the pump over 1000 psi.
4.3.5
Do not run the machine when there is inadequate water flow to
the inlet port. Insufficient water supply will damage the
components inside the pump and shorten the life of the machine.
4.3.6
The water supply hose must be at least 5/16” in diameter.
4.3.7
Do NOT use a power cable longer than 30 ft. All extension cables
must be rated for the required voltage and amperage, and be
outdoor rated with a grounding prong.
4.3.8
The water pressure at the inlet port should be at least 30 psi for
continuous operation.
4.3.9
Water temperature must not exceed 50°C/120°F and must be
well-filtered.
4.3.10
The inlet water must be filtered.
Sediment and contamination
will clog the pump internals as well as the misting nozzles. It is
recommended to use a water treatment or conditioning filter to
reduce and prevent the formation of solids in areas with hard
water or high mineral concentrations.
4.3.11
Before use, check the pump oil for deterioration. Check that inlet
fittings and high-pressure fittings are FIRMLY attached and fully
seated.
Summary of Contents for F10-04-009
Page 1: ...Misting Pump User Manual ...