HydraMaster Corporation
Page 3-2 : CTS 450 Owner’s Manual
CTS 450
Hot Carbonating Truckmount System
Carpet or Upholstery Cleaning
1. Fill solution tanks with A and B solution.
2. Position the Compressor Valve to CLEANING MODE.
3. Position the Solution Valve to CLEANING MODE.
4. Position cleaning mode switch to carpet mode.
5. Connect the solution and vacuum hoses to the tool.
6. Commence cleaning.
Notes:
-
If the Solution Valve is left in the PRIME position, the solution will evacu-
ate from the chemical tanks into the recovery tank.
-
If the solution tanks run dry, air will fill the system. After the solution tanks
have been filled, with solution, purging the air from the system may re-
quire several minutes. This can be expedited by turning the solution
valve to prime for 15 seconds, then returning the valve to cleaning mode.
Flood Extraction
1. Position Solution Valve to PRIME mode.
2. Position Compressor Valve to PRESSURE RELIEF.
3. Set the cleaning mode switch to EXTRACTION MODE.
4. Connect vacuum hoses and tool.
5. If equipped, switch Auto Pump Out to ON.
6. Disconnect out-going quick connects on chemical tanks.
Figure 3-2