Technical Data
The unit has the following technical data:
Hydraulic data
Filter Size
Differential
Volume
Unladen weight
(without the
OLF)
OXS-30LID
≤ 30 liters
approx. 45 kg
OXS-45LID
≤ 45 liters
approx. 49 kg
OXS-70LID
≤ 70 liters
approx. 55 kg
OXS-150LID
≤ 150 liters
approx. 78 kg
OXS-250LID
≤ 250 liters
approx. 89 kg
OXS-325LID
≤ 325 liters
approx. 131 kg
OXS-500LID
≤ 500 liters
approx. 145 kg
Permitted operating fluids
Mineral oils acc. to DIN 51524
Typical gas removal rate
4 l/h
Permissible viscosity range
15 … 300 mm/s²
15 … 200 mm/s² with OLFCM
Maximum fluid flow rate
IN / OUT
OXS-30LID / 45LID / 70LID
OXS-150LID / 250LID
OXS-325LID / 500LID
900 l/min
2700 l/min
5400 l/min
Permitted fluid temperature range
10 … 80°C
Electrical data
Supply voltage
see the name plate on the electric
motor
Power consumption
see the name plate on the electric
motor
Protection class to DIN 40050
see the name plate on the electric
motor