Maintenance
OXiStop OXS-LID/-C202
en-US
Page 63 / 96
MoWa OXS-LID-C202 4461688 en-us 2019-07-08.docx
2019-07-08
Bleeding the OLF 5 bypass flow filtration unit
WARNING
Hot fluid
Risk of burns
►
Make sure that hot fluid can exit when
bleeding.
NOTICE
Air in the OLF 5 bypass flow filtration unit
The filter element is not utilized completely
►
Bleed air from the OLF 5 bypass flow filtration unit after each standstill
/ filter element replacement, protective screen replacement.
Bleed air from the fluid filter via measurement connection (2.7) until fluid
begins to escape. To do this, attach a measurement hose (1602) to
measurement connection (2.7) and place the other end of the hose in a catch
tank for the oil.