Assembly, installation and commissioning
OXiStop OXS-LID/-C202
en-US
Page 39 / 96
MoWa OXS-LID-C202 4461688 en-us 2019-07-08.docx
2019-07-08
Hydraulic installation/assembly
Connect the hydraulic tank to your hydraulic system at the corresponding
connections.
Attach the OXS to the corresponding connections with the enclosed OLF 5
bypass flow filtration unit.
-
Connect the suction line to port "S" (ISO8434-1-28L M36x2).
-
Connect the pressure line to port "P" (ISO8434-1-22L M30x2).
- Connect the lines to the corresponding ports "S" and "P" on the
OLF 5 bypass flow filtration unit.
-
Select hoses that are as short as possible, with a nominal size
≥
the ports "S" and "P".
-
Attach the enclosed OLF 5 bypass flow filtration unit as close as
possible to the OXS.
Note that the pressure line must be designed for a load of
at least 10 bar.