6 Installation / commissioning
In this chapter you will find instructions regarding the mechani-
cal and hydraulic installation of the filter housing.
6.1 Mechanical/hydraulic installation
Mount the filter housing in any random position using 2
hexagon head screws M 12 in accordance with ISO 4014 /
ISO 4017. A preferred direction of flow is defined at the works
through the element removal label.
Fig. 8:
Mounting the filter housing
Before mounting take note of the element removal label. Use
this side as the inlet (IN). This way the filter elements functions
as a bag and the contaminant particles are situated in the filter
element and not in the filter housing during a filter element
change.
Make sure that no stresses or vibrations are transmitted to the
filter housing. Use hoses or expansion joints if necessary.