HYDAC FILTER SYSTEMS GMBH
Setting up / assembly / integration of the filter unit | 5
BeWa MFU-30E 4073898a en-us web
49 / 88
5.6 Attaching/connecting the suction/pressure hoses
(accessories)
The suction/pressure hoses from the filter unit
are matched to the filter unit. If you use different con-
nection hoses, take into account the pressure loss when con-
necting suction/pressure hoses.
The IN / OUT connection dimensions on the filter unit can be
found in Chapter
NOTICE
High solid particle contamination in the fluid / at the bottom of
the tank
The pump is damaged / destroyed.
u
Do not suction the fluid directly at the bottom of the tank
where the sediment is.
The highest level of contamination is found at the bottom of
the tank. All impurities and other particles are deposited on
the bottom of the tank.
Prevent aeration of the medium by fully immersing the lance
in the medium.
Ensure that the lance is always below the level of the oil dur-
ing operation.
Check the hoses for damage and brittleness. Replace dam-
aged or brittle hoses immediately. Doing so avoids leakages.
Put the hoses with the lance, without any tension and or twist,
into the corresponding tank. Put the hose with the lance into
the corresponding tank without any tension or twist. Secure
the hose so that it cannot fall out or float.
Check that no shut-off devices in the lines/hoses are ob-
structed. Make sure there is a depressurized outlet.
1
2
3
4
5
6
7
8
9
A
Summary of Contents for MFU-30E
Page 88: ...www hydac com ...