HYDAC FILTER SYSTEMS GMBH
Performing Maintenance | 8
BeWa MFU-30E 4073898a en-us web
71 / 88
ü
Switch off the filter unit and remove the lance from the
reservoir and/or close the shut-off device in order to pre-
vent any subsequent flow of the fluid.
1.
First disassemble the suction hose upstream of the inlet
connector (700).
2.
Loosen the inlet connection counterclockwise (700) us-
ing the wrench
= 50 mm.
3.
Pull the protective screen (710) out with the long-nosed
pliers.
O
Disassembly of the protective screen is complete.
Proceed as follows to install:
ü
The inlet connector (700) is removed.
4.
Insert the cleaned protective screen (710) into the filter
head. While doing so, ensure that the opening points to-
wards the inlet connector.
5.
Screw in the inlet connector (700) by hand in a clock-
wise direction and tighten it using a wrench
= 50
mm.
6.
If necessary, mount the suction hose on the inlet con-
nector (700).
O
The assembly of the protective screen is complete.
1
2
3
4
5
6
7
8
9
A
Summary of Contents for MFU-30E