6 Manual operation
Select the required operating mode as described in Chapter
Selecting the operating modes [
port/pressure port to the containers to be cleaned and switch
the filter unit on at the main switch.
To monitor the service life of the filter element , the filter unit is
equipped with a clogging indicator (optical differential pressure
indicator).
Check this daily through a visual check during operation. See
Chapter
Observe the optical clogging indicator [
When the clogging indicator has responded or the pointer is in
the red zone, exchange the filter element.
If the container to be filled is full or if the required oil cleanli-
ness has been achieved, switch off the filter unit with the main
switch. Empty the contents of the suction and pressure hoses
into the respective containers and secure the cable and hoses
as described in Chapter