FAM 15/30/50/70
Troubleshooting
HYDAC Filter Systems GmbH
en
Page
57 /
68
BEWA FAM15-70Siem 3099574e en 2009-10-08.doc
2008-10-06
Inlet (IN) clogged
Step
Description
1. Malfunction:
"Inlet clogged"
2.
Cause: Medium cannot make its way into the vacuum chamber
3.
Check locking features in the suction line. Open if blocked.
Check suction strainer and clean if necessary
4.
To reset the failure, press the RESET key
5.
Does malfunction reappear after
≈
4 minutes?
->a. Yes
-> proceed to Step 7.
6.
->b. No
-> proceed to Step 8.
7.
Check the following points:
-
Check the suction pipe for cross-section constriction
-
Check the functioning of vacuum pump in manual mode
-
Check the position of the shut-off device in the suction line
8.
The failure is repaired.