Rotary vane vacuum pump
(only for model code FAM-xx-x-x-x/xxx-xxx-xx-xx-D-x-x/xxx)
As a basic rule, the rotary vane vacuum pump is not filled with oil at the time the
FAM is delivered. A sufficient amount of vacuum pump oil for the initial filling is
included in the scope of delivery.
NOTICE
Operation without vacuum pump oil
The rotary vane vacuum pump will be destroyed.
►
The rotary vane vacuum pump requires oil as its operating medium.
►
Check the oil level before star-up, topping up with vacuum pump oil VE101
if necessary.
The maximum filling amount for vacuum pump oil VE101 is:
FAM 25
≈
0.3 liter
FAM 45-95
≈
1.0 liter
The water level is monitored automatically by the integrated float switch while the
FAM is in operation. A message will appear on the control panel when the MIN MAX
filling level has been reached.
Synthetic vacuum pump oil in accordance with DIN 51506, Group VDL, ISO VG100
must be used for topping up.
The vacuum pump oil can be ordered from HYDAC:
Description
Part no.:
Vacuum pump oil VE101
DIN 51506, Group VDL, ISO VG100, synthetic
1 liter
06018128
Vacuum pump oil VE101
DIN 51506, Group VDL, ISO VG100, synthetic
5 liters
06018129