V-pump fill level min/max
Step
Description
Malfunction:
"Filling level V-pump min/max"
1.
Press RESET key
->a. Error message lapsed
-> proceed to Step 6.
2.
->b. Error message still illuminated
-> proceed to Step 3.
3.
Check oil level; fill up or drain oil as necessary
Check level sensor of the vacuum pump and the supply lines
->a. Fault appears again
-> proceed to Step 5.
4.
->b. The fault does not recur
-> proceed to Step 6.
5.
Replace damaged parts
6.
The failure is repaired.