EN
34
DE/EN/FR 18.055.H.7/07.19
11. Technical specifications
Input data:
Measuring ranges
16; 40; 100; 250; 400; 600 bar
Overload pressures
32; 80; 200; 500; 800; 1000 bar
Burst pressure
200; 200; 500; 1000; 2000; 2000 bar
Mechanical connection
Threaded port G1/4 DIN 3852
Torque value
20 Nm
Parts in contact with medium
Mech. connection: Stainless steel
Output data:
Accuracy to DIN 16086,
EDS 1700-P:
≤
±0.5 % FS max.
max. setting
EDS 1700-N:
≤
±1.0 % FS max.
(Display, Analogue output)
Repeatability:
EDS 1700-P:
≤
±0.25 % FS max.
EDS 1700-N:
≤
±0.5 % FS max.
Temperature drift EDS 1700-P
≤
± 0.02 % FS / °C max. zero point & range
Temperature drift EDS 1700-N
≤
± 0.03 % FS / °C max. zero point & range
Analogue output:
Signal (selectable)
4 .. 20 mA, ohmic resistance
≤
400
Ω
0 .. 10 V, ohmic resistance
≥
2 k
Ω
Switching outputs*:
Type
4 relays with change-over contacts in 2 groups
(common supply of each group connected)
Switching voltage
0.1 .. 250 V AC, 12 .. 32 V DC
Switching current
0.009 .. 2 A per switching output
Switching output
max. 50 W / 400 VA
(for inductive load, use varistors)
Switching cycles
20 million min. load
1 million max. load
Reaction time
approx. 20 ms
Ambient conditions:
Compensated temp. range
-10 .. + 70 °C
Operating temperature range
-25 .. +60 °C
Storage temperature range
-40 .. +80 °C
Fluid temperature range
-25 .. +80 °C
mark
EN 61000-6-1, EN 61000-6-2,
EN 61000-6-3, EN 61000-6-4
Vibration resistance to
≤
5 g
DIN EN 60068-2-6 (0 .. 500 Hz)
Shock resistance to
≤
10 g
DIN EN 60068-2-29 (1 ms)
Protection class to IEC 60529
IP 65