EN
35
DE/EN/FR 18.055.H.7/07.19
12. Pin connections
relay 4
= switch. point 4
relay 3
= switch. point 3
relay 2
= switch. point 2
relay 1
= switch. point 1
analogue output (0V)
analogue output ()
supply (0V)
supply (+ UB)
Other data:
Supply voltage
22 .. 32 V DC
Current consumption
approx. 200 mA
Residual ripple
≤
10 %
Display
4-digit 7 segment LED display,
red, height of digits: 13 mm
Electrical connection
14-pole, terminal block
Housing material
aluminium, anodised
Weight
approx. 800 g
Note:
FS
(
F
ull
S
cale) = relative to the full measuring range
Reverse polarity protection of the supply voltage, excess voltage, override,
short circuit protection are provided.
earth
*
Setting ranges of the switching outputs:
– Switching point
relay 1 to 4: 1.5 .. 100 % FS
– Switch-back point
relay 1 to 4: 1 .. 99 % FS
– Switch-back hysteresis relay 1 to 4: 1 .. 99 % FS