EN
31
DE/EN/FR 18.055.H.7/07.19
Setting
Display
Setting Pre-
range setting
Analogue output (Output)
MAMP/ VOLT
"MAMP": The analogue output supplies
VOLT
a 4..20 mA signal.
"VOLT": The analogue output supplies
a 0..10 V signal
Hidden basic settings menu
YES/NO NO
(Hide)
"YES": The basic settings menu is
hidden and can only be
accessed if the keys for calling
up the menu are held down
when the supply voltage is
switched on.
Version number (Version)
Display of the current software version
(for reference only)
To end basic settings (End)
YES/NO NO
8. Programming enable
The unit has 2 types of programming enable which must both be set to "ON" to
change the settings. The software programming enable can be set or removed
during operation. It provides protection from unintentional alteration.
A programming disable via the hardware programming enable means that no
change to the settings can be carried out during operation. This serves, for
example, as a safety function or as protection against unauthorised alterations.
8.1. ALTERING THE SOFTWARE PROGRAMMING ENABLE
press both keys
simultaneously and
hold down for 3s
display
alter setting using individual key:
ON = programming possible
OFF = programming disabled
pressure
display