General data
Mounting position
Any (recommended: vertical position)
Self-diagnosis
Continuously with error display
via status LED
Measurement categories
ISO 4406:1999
Ambient temperature range
-30° ... +80° C / -22° ... 176° F
Storage temperature range
-
40° ... +80° C / -40° ... 176° F
Relative humidity
Max. 95%, non-condensing
Sealing material
FPM
Electrical safty class
III (low voltage protection)
Protection class
IP67
Weight
1.3 kg
Electrical data
Connection plug
M12x1, 8 pole, specified in DIN VDE 0627
Power supply voltage
9 – 36 V DC, residual ripple < 10% (reverse
polarity protection)
Power consumption
3 Watt max.
Analog output
2-conductor technology
0 - 5 V active output
HSI (
H
YDAC
S
ensor
I
nterface)
1 wire, half duplex