ContaminationSensor CS1000
CS1220 VIMS Features
HYDAC Filter Systems GmbH
en
Page 22 / 36
CS1000 CAT-VIMS3478916 en 2009-04-15.doc
2009-04-15
Electrical connection of the CS1000
Pin assignment
Pin
Assignment
1
Supply voltage 9 – 36 V DC
2
Analog ISO < 4µm
3
GND for supply voltage
4
GND for analog outputs
5
HSI (
H
YDAC
S
ensor
I
nterface)
6
Analog ISO < 6µm
7
Analog ISO < 14µm
8
Analog status
The analog output is an active source 0 - 5 V DC.
There is contact between the plug housing and the CS housing.
The analog output feature an open connector out that is able to sink the 1 mAmp
drive current from the ECM and will not interfere with the 22k pull up resistors.
Situation
Signal level for ECM
Cable shortcut
0V
Cable break
5V
Summary of Contents for ContaminationSensor CS1220 VIMS
Page 35: ...Notes ...