ContaminationSensor CS1000
CS1220 VIMS Features
HYDAC Filter Systems GmbH
en
Page 20 / 36
CS1000 CAT-VIMS3478916 en 2009-04-15.doc
2009-04-15
Flow rate, differential pressure
p
∆
and viscosity
ν
characteristics
Differential pressure
p
∆
and viscosity
ν
characteristics. All the values indicated in
the figures below apply regardless whether the direction of flow is A->B or B->A.
The permissible measured volumetric flow must be between 30 ml and 300 ml/min.
If you are unable to achieve these flow values, we carry various
ConditioningModules in our extensive line of accessories.
20
Qmin = 30 ml/min
100 ml/min
160 ml/min
Qmax
= 300
ml/min
0
10
20
30
40
50
60
70
80
90 10
0
11
0
12
0
13
0
14
0
15
0
16
0
17
0
18
0
19
0
20
0
18
16
14
12
10
8
6
4
2
0
p
[b
a
r]
∆
[mm /s]
ν
2
1 bar
46 mm /s
2
50
Qmin = 30 ml/min
100 ml/min
Qma
x = 3
00 m
l/min
20
0
30
0
40
0
50
0
60
0
70
0
80
0
90
0
10
00
45
40
35
30
25
20
15
10
5
0
160 ml/
min
p
[b
a
r]
∆
[mm /s]
ν
2
For example:
You are using a fluid with a viscosity
ν
of 46 mm²/s at a differential pressure
p
∆
of
1 bar, so that you achieve a flow rate of approx. 100 ml/min.
The flow rate depends on the viscosity of the medium and the differential pressure