10 | Appendix
HYDAC FILTER SYSTEMS GMBH
78 / 88
BeWa FCM 3160267e en-us lq
Permitted temperature range
-30 … +100°C
Connector threads
G ½
Installation space required
According to
Maximum tightening torque
33 Nm
Switching type
N/C or N/O
(change-over contacts)
Maximum switching voltage
/-L24 = 24 V DC
/-L48 = 48 V DC
/-L115 = 115 V AC
/-L230 = 230 V AC
Max. switching voltage at re-
sistive load
60 W
100 VA AC
Switching capacity
ohmic 3 A @ 24 V DC
ohmic 0.03 to 5 A @ 230 V AC
Electrical connection
Male connection M20
Female connector to
DIN EN 175301-803
Protection class in accordance
with DIN 40050
IP 65 (only if the connector is
wired and fitted correctly)
Tab. 16:
Differential pressure indicator, electrical VM x D.x / -Lxx
10.4 Finding a Customer Service team
The contact data such as the telephone numbers, e-mail and
mailing addresses for the hotline, product support, customer
service, branch offices, service partners for servicing, repair
and spare parts can be found, always updated, at our home-
page
HYDAC SYSTEMS & SERVICES GMBH
Friedrichsthaler Str. 15a, Werk 13
66450 Neunkirchen - Heinitz
Germany
Phone:
+49 6897 509 883
Fax:
+49 6897 509 324
Summary of Contents for 3.6.4 FCM 100-K Series