3 | Overview of the filtration unit
HYDAC FILTER SYSTEMS GMBH
30 / 88
BeWa FCM 3160267e en-us lq
3.6.3 FCM 100-L-… / FCM 100-F-…
The filter unit FCM 100-L-… / FCM 100-F-… has the following
technical data depending on the version:
Permissible operating fluid
Mineral oils according to DIN
51424
Permitted operating pres-
sure
≤ 6 bar
Pump type
Vane pump
Hydraulic connections:
Suction hose
Pressure hose
NW 38 (1½ “ according to
ISO 228)
NW 25 (M36x2)
Sealing material
NBR (FPM optional)
Nominal flow rate
100 l/min
Permissible viscosity range 15 … 400 mm²/s
Permitted pressure at suc-
tion port (IN)
-0.4 … 0.6 bar
Permitted fluid temperature
range
-10 … 80°C
Permitted ambient tempera-
ture range
-10 … 40°C
Permitted storage tempera-
ture range
10 … 40°C
Permitted relative humidity
during storage
≤ 95 %, non-condensing
Air conditions
Clean, salt-free air, not near oxi-
dizing substances (rust film)
Storage duration
unlimited
Replace all the seals before
commissioning after a storage
duration of ≥ 2 years.
Degree of protection
IP55
Summary of Contents for 3.6.4 FCM 100-K Series
Page 22: ...3 Overview of the filtration unit HYDAC FILTER SYSTEMS GMBH 22 88 BeWa FCM 3160267e en us lq ...
Page 85: ......
Page 86: ......
Page 87: ......
Page 88: ......