HYDAC FILTER SYSTEMS GMBH
Setting up / assembly / integration of the filter unit | 5
BeWa FCM 3160267e en-us lq
45 / 88
5.4 Making the electrical connections
Depending on the version, the filter unit has different drive mo-
tors (different voltage / output / number of phases, etc.). Follow
the instructions in the next section to electrically connect the fil-
ter unit.
5.4.1 Connecting the filter unit with a single-phase
electric motor
For the version with a single-phase electric motor, the filtration
unit is supplied ready for connection with a plug.
1.
Remove the connector cable from its holder and unwind
it completely.
2.
Before plugging in the power plug, make sure that the
on/off switch is in the 0 or OFF position.
3.
Check that the voltage and frequency are correct. You
will find the filter unit's electrical data on the electric mo-
tor's name plate.
4.
Plug the power plug into a suitable power outlet.
5.
Switch the filter unit on or off using the switch on the mo-
tor terminal box.
Depending on the version, the filter unit has ther-
mal protection in the motor windings and a motor
protection switch in the junction box to protect it
from electrical overload.
Summary of Contents for 3.6.4 FCM 100-K Series
Page 22: ...3 Overview of the filtration unit HYDAC FILTER SYSTEMS GMBH 22 88 BeWa FCM 3160267e en us lq ...
Page 85: ......
Page 86: ......
Page 87: ......
Page 88: ......