Filtromat – OF5 C
5.3
Shutting down the OF5 C
When shutting down and/or disposing of the OF, observe local guidelines and
regulations pertaining to occupational safety and environmental protection. This
applies in particular to the oil in the filtration unit and OF components covered with
oil.
5.4
Disposing of the OF5 C
When shutting down and/or disposing of the CSM, observe local guidelines and
regulations pertaining to occupational safety and environmental protection. This
applies in particular to the oil in the unit, components covered with oil and electronic
components.
After disassembling the unit and separating the various materials, they can be
reused or disposed of properly in accordance with local regulations.
6
Errors and Troubleshooting
Error Message
Cause(s)
Remedy
Cause: pronounced
contamination of the
medium
Replace filter element
Contamination retention
capacity of the filter
element reached.
Replace filter element
Differential pressure > 2.5
bar
Viscosity too high
Warm medium up
The pump is conveying in
the wrong direction.
Check the sense of
rotation of the motor and,
if necessary, reverse the
phases.
No flow
Suction hose not deep
enough in the container
Sufficiently immerse the
suction hose in the
medium
No function
Not connected to power
supply.
Check the connection to
the power supply: plug,
cable and power outlet.
HYDAC Filtertechnik GmbH
en
Page 24
BeWa OF5C 3160333a en
2008-02-06