FAM 15/30 ATEX
Performing maintenance / inspection
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 68 / 84
BeWa FAM15_30 Atex 3197970c en-us 2012-08-08.doc
2012-08-08
Clean the suction strainer.
NOTICE
Missing suction strainer
Pump is disrupted
►
Replace suction strainer
►
Clean the suction strainer regularly.
To protect the pump from coarse contamination particles and other foreign bodies, a
dirt trap with a strainer insert is fitted at the pump inlet.
This strainer insert must be cleaned at regular intervals, e.g. by flushing it with
solvent or blow-flushing it with compressed air.
1. Unscrew the screw plug (1)
counterclockwise with an open-jaw
wrench (50 mm).
2. Remove the strainer insert (3) and
clean it.
3. Check strainer insert (3) and sealing
ring (2) on the screw plug for
damage. Replace it if necessary.
4. Insert the strainer insert (3).
5. Screw in the screw plug by hand,
and tighten it using the open-jaw
wrench (50 mm).
6. Check the suction strainer fitting for
leaks after commissioning.
1
2
3