FAM 15/30 ATEX
Starting up the FAM
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 41 / 84
BeWa FAM15_30 Atex 3197970c en-us 2012-08-08.doc
2012-08-08
Shut off FAM
Press key "Run-down [S2]". Now the unit starts with the after-running phase. The
inlet valve closes, the vacuum pump is switched off, and the vacuum chamber is
emptied.
Wait until the lamp H2 goes out, then move the main switch to the "Off" position.
The system is now switched off.
FAM in manual operation
The following components can be switched on / off or opened / closed by hand in
manual operation:
Vacuum
pump
Evacuation
pump
2/2 directional inlet valve
Manual operation is very helpful when searching for a fault. You can
switch pumps on / off in a targeted way.
To switch to manual operation, press the button
"Malfunction [S3]"
for
at least 6
seconds
.
After you have switched to manual operation, the operating status lamp H4 flashes.
In manual operation, the allocation of buttons S1-S3 is as follows
Inscription
DESCRIPTION
S1
Start delay
Switching evacuation pump On/Off
S2
Run-down
Switching vacuum pump on/off
S3
Malfunction
Opening/closing inlet valve
After a button is pressed, the corresponding operating status lamp lights up.
You can perform individual functions for a maximum of 15 minutes.
The FAM then automatically switches off.
Once all functions have been deactivated, the FAM exits manual
operation automatically after 10 seconds.