FAM 15/30 ATEX
Error messages / troubleshooting
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 44 / 84
BeWa FAM15_30 Atex 3197970c en-us 2012-08-08.doc
2012-08-08
[H5] Vacuum chamber overfilled
Step
DESCRIPTION
Malfunction:
"Reactor overfilled"
1.
Press RESET key
2.
Select manual menu 1, start evacuation pump
3.
Can vacuum chamber be emptied within 3.5°minutes from level 03 to
level 01?
->a. Yes
-> proceed to Step 5.
4.
->b. No
-> proceed to Step 6.
5.
Excessive foaming -> vacuum in the vacuum chamber too high –
reduce vacuum (e.g. from 300 mbar
(abs)
-> 400 mbar
(abs)
)
6.
Check the evacuation pump for proper functioning
7.
The failure is repaired.