FAM 15/30 ATEX
Performing maintenance / inspection
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 67 / 84
BeWa FAM15_30 Atex 3197970c en-us 2012-08-08.doc
2012-08-08
11. Put the intermediate piece (b) on the lower
section (c).
Mount the lower housing tensioning clamp (1),
and tighten it with a torque of 20 Nm. Secure
using the lock nut.
Put the cover (a) on the intermediate piece (b).
Mount the upper housing tensioning clamp (2)
and tighten it with a torque of 20 Nm. Secure
using the lock nut.
We recommend applying lubricant
containing a slip additive to the threads of the
housing tensioning clamp each time filters are
changed so that it remains easy to remove.
Lubricant containing a slip additive - HYDAC
p/no..: 3066287
12. Open all shut-off valves on the FAM (inlet and
outlet).
Switch on the FAM at the main switch.
13. Fill the filter housing slowly.
Slightly undo the air bleed screw (x). The air in the
filter housing can escape via the slot on the air
bleed screw.
Bleed the filter housing through the air bleed
screw (x) until fluid comes out.
Tighten the air bleed screw.
14. The filter element change is now complete.
Checking the fault indicator lamp
After the FAM is switched on, all fault indicator lamps light up for 2 seconds. Check
to see whether all fault indicator lamps light up. Replace any defective lamps
immediately.