FAM 15/30 ATEX
Error messages / troubleshooting
HYDAC FILTER SYSTEMS GMBH
en(us)
Page 43 / 84
BeWa FAM15_30 Atex 3197970c en-us 2012-08-08.doc
2012-08-08
Signal
Inscription
Cause
Remedy
with fresh water.
H13
Dry-running
Evacuation Pump
Too little medium is
being sucked into the
vacuum chamber.
Flow protection of the
dewatering pump (dry-
running protection)
Check suction strainer,
check suction pipe,
suction hose could be
attached to the floor.
Check vacuum pump,
and clean as required.
H14
Level switch
01/02/03
Level switch defective.
Check level switch and
replace if necessary.
H15
Pressure V-pump Pressure in the vacuum
pump is too high.
Exhaust filter cartridge is
used up.
Replace exhaust filter
cartridge (see operating
instructions of vacuum
pump).
Error
Cause
Remedy
Oil mist is coming out of
the exhaust line of the
vacuum pump.
Exhaust filter cartridge is
used up.
Replace exhaust filter
cartridge (see operating
instructions of vacuum
pump)
The vacuum pump has an
unusually high oil
consumption.
Exhaust filter cartridge is
used up.
Replace exhaust filter
cartridge (see operating
instructions of vacuum
pump)