10 | Finding / rectifying errors
HYDAC FILTER SYSTEMS GMBH
78 / 92
BeWa FCU1210 3545830b en-us lq
Disruption / error
LED
Status-LED
Display
Status /
Possible causes
Solution
If the fault recurs, contact HY-
DAC service department.
LED: Red
Status LED:
Error during automatic ad-
justment.
Wait for a few more measure-
ment cycles.
LED: Red
Status LED:
Error in the measurement
cell.
If the fault recurs, contact HY-
DAC service department.
Tab. 11: List of disruptions/errors