4 | Overview
HYDAC FILTER SYSTEMS GMBH
26 / 92
BeWa FCU1210 3545830b en-us lq
Hydraulic data
Permissible viscosity
range
2 … 350 mm²/s / 33 … 1622 Sus
(for hydraulic oil up to ISO VG 68)
Suction height
≤ 1 m / ≤ 39.37 inches
Suction hose INLET
DN4, open-end, color: clear-trans-
parent,
Length = 0.3 m
Return hose OUTLET
DN7, open-end, color: clear-trans-
parent,
Length = 1.5 m
Tab. 5:
Hydraulic data
Electrical data
Power supply
24 V DC, ± 20%, residual ripple
≤ 10%
Power consumption
≤ 100 W
Current consumption
≤ 4 A
Operating mode
S3, periodic intermittent duty as per
DIN EN 60034-1 / DIN VDE 0530
part 1 relating to a useful life of 10
minutes.
Relative duty cycle
40 %
Degree of protection
IP 50 (open, in operation)
IP 67 (closed)
Protection class
III (low voltage protection)
Tab. 6:
Electrical data
General data
Emission sound pres-
sure level L
PA
< 70 db(A)
Material of sealings
FKM (FPM, Viton
®
), NBR
Permitted temperature
range of fluid
0 … 70 °C / 32 … 158 °F
Permitted ambient tem-
perature range
0 … 45 °C / 32° … 113 °F