Operating filter membrane holder / Removing filter membrane
CTM-EF 1000 series
en(us)
Page 27 / 52
BeWa CTM-EF 3509157c en-us 2018-10-18.docx
2018-10-18
Filter membrane holder with clamp
NOTICE
Operation without an intermediate ring / supporting sieve
Leak in the filter membrane holder
►
The filter membrane holder only seals effectively when:
- a vacuum is applied
- a supporting sieve is inserted with a filter membrane
►
It is not possible to use two intermediate rings.
Squeeze the clip together by the handles (1). Push the clip over the filter
membrane holder (2). Carefully release the clip handles - the clip’s spring
force (3) will press the two halves (67.1 + 67.2) of the filter membrane holder
(with the intermediate ring) together.
Make sure that an intermediate ring and two supporting sieves are used
when a clip is used.