Operating filter membrane holder / Removing filter membrane
CTM-EF 1000 series
en(us)
Page 28 / 52
BeWa CTM-EF 3509157c en-us 2018-10-18.docx
2018-10-18
Filter membrane holder CTMH (ContaminationTest Membrane Holder)
The design presses the filter membrane in the lower part (2) of the filter
membrane holder function-tight to the upper part.
The filter membrane holder CTMH has three height positions for threefold
cascading. Select the height according to your desired cascading.
To seal the filter membrane holder it is sufficient to turn the upper part 90°.
Note that the wrench size at the lower part to the left and right is visible in
order to insert the lower part into the upper part.
CAUTION
"G60 Spezial" test liquid
Health hazard
►
Make sure that there is adequate ventilation.
►
Always wear protective gloves.
►
Always wear eye protection.