Model
Rev.
Page
HMK-056
Ver1.01
55
SUB+’1’
[Name]
Choice of rule 1
[Format]
ASCII
SUB
1
Hex
1A
31h
Decimal
26
49
[Descript] Choose the rule 1 of two rules (rule1 or rule2).
SUB+’2’
[Name]
Choice of rule 2
[Format]
ASCII
SUB
1
Hex
1A
32h
Decimal
26
50
[Descript] Choose the rule 2 of two rules (rule1 or rule2).
SUB+’W’+nL+nH+kL+kH
[Name]
Writing the rule data
[Format]
ASCII
SUB
W nL nH kL kH
Hex
1A
57h nL nH kL kH
Decimal
26
87 nL nH kL kH
[Range] 0≤nL+nHx256≤448, (0≤nL≤255, 0≤nH≤3)
0≤kL+kHx256≤448, (0≤kL≤255, 0≤kH≤3)
[Descript] It writes 1 from nL+nHx256 to kL+kHx256.
[Caution] If the range is exceed, the data will be ignored.
If the writing is set up, the data is not erased, until you do power off
or you receive the command (the rule clear).
SUB+’C’
[Name]
Rule CLEAR
[Format]
ASCII
SUB
C
Hex
1A
43h
Decimal
26
67
[Descript] It clears all of data (as) zero you choosed.
[Caution] Please use this command, once you do rewrite the rule data.
If you need to speed up the processing, you use the command on/off.
SUB+’O’
[Name]
Rule ON
[Format]
ASCII
SUB
O
Hex
1A
4Fh
Decimal
26
79
[Descript] Once you set up the command, the rull will be printing with the character or font.