Model
Rev.
Page
HMK-056
Ver1.01
42
GS+’(’+’K’+pL+pH+fn+m (fn=97)
[Name]
Operating thermal head partially
[Format]
ASCII
GS
(
K
pL
pH
fn
m
Hex
1D
28h
4Bh
pL
pH
fn
m
Decimal
29
40
75
pL
pH
fn
m
[Range] pL=2, pH=0, fn=97
0≤m≤2
[Initial Value]
m=0
[Descript]
Set the operation of partial thermal head
[Caution]
This function will be effective once the power capacity is short.
The Second division of electric current (ampere) will be half than the first division.
m
Partial operation
0
Initial setting (first division)
1
First Division
2
Second Division
GS+’B’+n
[Name]
Reverse printing in black
[Format]
ASCII
GS
B
n
Hex
1D
42h
n
Decimal
29
66
n
[Range]
0≤n≤255
[Initial Value]
n=0
[Descript]
Reverse printing in black
n=0, standard printing
n=1, reverse printing in black
GS+’H’+n
[Name]
Select the printing position of HRI characters (Barcode)
[Format]
ASCII
GS
H
n
Hex
1D
48h
n
Decimal
29
72
n
[Range]
0≤n≤3
[Initial Value]
n=0
[Descript]
Select the printing positions of numerical value & characters
n
Printing Position
0
Non printing
1
Above the barcode
2
Below the barcode
3
Both above & below barcode