SUB+‟W‟+nL+nH+kL+kH
Function
WRITE rule line data
Code
ASCII SUB
W
nL
nH
kL
kH
Hex
1A
57h
nL
nH
kL
kH
Decimal 26
87
nL
nH
kL
kH
Range
0≤nL+nH×256≤640、(0≤nL≤255, 0≤nH≤3)
0≤kL+kH×256≤640、(0≤kL≤255, 0≤kH≤3)
Description
Writes 1 from nL+nH×256 to kL+kH×256 on the selected
rule line.
It is ignored if the defined range is exceeded.
Once written, the data is preserved without being erased until the clear rule
lines command is received or the power is turned off.
SUB+‟C‟
Function
Clears rule line data.
Code
ASCII
SUB
C
Hex
1A
43h
Decimal 26
67
Description All selected rule lines are cleared to 0.
To speed up processing, rule line print ON/OFF is used for printing/non-
printing of rule lines written once, and this level=>Command is used to re-
write rule line data.
SUB+‟O‟
Function
Rule line ON
Code
ASCII
SUB
O
Hex
1A
4Fh
Decimal 26
79
Description
Rule lines are set to Valild(ON). When it is enabled, it is written once and the
selected rule lines are printed along with the character.