background image

Poseidon 4002 

– Manual 

HW group 

 

 

 

www.HW-group.com

 

 

 

Poseidon will send alarm 
activation and alarm deactivation 
for each contact and/or sensor. 

 

E-mail format cannot be changed; 
sensors may have custom names. 

 

Yellow background in a line with a 
sensor or an input means that the 
safe range is exceeded but alarm 
notification is off. 

 

 

FAQ 

 

Inputs wiring 

Inputs  

 

 

 
 

 

 

 

 

 
 
 
 
 
Note:

  

Configuration changes must be confirmed by clicking the Apply Changes button.

 

 

 

Poseidon family manual 

For a detailed description of the configuration and all tabs in the interface, 

see the “

Poseidon Family

” manual. It is available on the web and the 

install CD. 

TIP 

Enter sensor name (will be 

shown in E-mail, SMS or 

SNMP traps)

 

ALARM CONTACT STATUS:

 

 

Active if On

 

 

Alarm when the contact 

closes

 (1 = On) 

 

Active if Off 

 

Alarm when the contact 

opens

 (0 = Off) 

 

Inactive 

 

No alarm

 

REACTION TO CONTACTS: 

 

Inactive 

  Send a 

 SNMP Trap 

  Send an

 E-mail 

  Send 

Email and SNMP 

Trap 

0 (Off)

1 (On)

Summary of Contents for Poseidon 4002

Page 1: ...Poseidon 4002 MANUAL...

Page 2: ...Poseidon 4002 Manual HW group www HW group com...

Page 3: ...terminals ETHERNET 10 or 100 10 Mbps DIP switch Configuration switches default is Off Off OUTPUTS Two 50V rated switch over relay contacts POWER OUT 12V supply for sensors SENSORS S1 to S4 ports for...

Page 4: ...Control PowerEgg Power detector Power control Remote reset 10m C C C RH Temperatue probe 3m Temperature probe for Rack montage Closed Door detector Dry Contact input Smoke detector Water Leak detecto...

Page 5: ...up If the Ethernet connection works properly the LINK LED lights up after a short while and then flashes whenever data is transferred activity indication 2 Configuring the IP address UDP Config UDP Co...

Page 6: ...the Apply Changes button to save the settings You may also use the following utilities to configure the IP address UDP Config for Linux RS 232 serial port any terminal program 9600 8N1 DIP1 ON restart...

Page 7: ...UP The WWW page displays current states of inputs and outputs Click the Graphic Flash SETUP link to open the graphical configuration interface Flash Setup Detailed configuration in Flash Setup Device...

Page 8: ...IP range SNMP SNMP SNMP Trap configuration ports and alarm recipients Email SMS Configuration and test Log Time Time configuration NTP server Sensors Device name sensor names status overview Outputs...

Page 9: ...t Gateway IP address 2 DNS server in network settings 3 SMTP server and port 4 Authentication turned on correct username and password 5 Spam filter for your mailbox is disabled 1 Supported GSM modem c...

Page 10: ...ensors and displays detected sensors Sends a SMS if the Safe Range for this sensor is exceeded To avoid numerous false alerts by e mail or SMS whenever the reading fluctuates around the threshold you...

Page 11: ...onfiguration changes must be confirmed by clicking the Apply Changes button Poseidon family manual For a detailed description of the configuration and all tabs in the interface see the Poseidon Family...

Page 12: ...output is active if at least one of the inputs or sensors is in alarm o On if value equal to Trigger The output is active if the sensor reading matches the Target Value o On if value higher than Trigg...

Page 13: ...e network using the A address by default at port 80 over service xml The communication takes place using the SOAP protocol therefore the sending Poseidon unit retries sending the SMS if the connection...

Page 14: ...application to process alarms The database can be accessed from a MS EXCEL sheet or through an API examples are available for NET VB C Borland C Delphi Microsoft C HWg PDMS Free version for 3 sensors...

Page 15: ...veral most recent ones and processes conditions and alarms Alerts to readings within an alarm range are sent by e mail or by SMS via a GSM modem connected to the PC MonTemp subsequently processes stor...

Page 16: ...Poseidon 4002 Manual HW group www HW group com Technical specifications 182 mm 483 mm 19...

Page 17: ...Relay contact outputs each output controls a NO and a NC contact Configuration DIP switches o DIP1 On activates Serial SETUP mode 9600 8N1 Restores factory defaults when 5x toggled within 5 seconds a...

Page 18: ...port RxD TxD RTS CTS GND Usage GSM modem Serial setup configuration with Dip1 ON POWER input Port POWER 9 15V DC Type Main device power input typically 400 mA external devices Connector Jack barrel in...

Page 19: ...from the rest of the device ID range Outputs use ID addresses from 151 to 180 Dry contact inputs Digital input terminals may be connected to voltage free contacts or the GND pin The inputs are electr...

Page 20: ...an take advantage of the HWg SDK Software Development Kit with an ActiveX interface and ready made examples VB Visual Basic 6 0 3xx examples Borland C 1xx examples Microsoft Visual C 2xx examples C NE...

Page 21: ...he update fails upload the firmware over RS 232 Firmware in the HWg format is available on our website or on the supplied CD Load defaults Reset the device to factory defaults clear all the passwords...

Reviews: