5.7 T
roUble
sHooTinG
Trouble
Probable cause
Remedy
Uncommanded
machine
shutdown
Work table limit switch
actuated.
• Limit switch out of adjustment. Manually move worktable
until limit switch is clear of limit switch trip ramp. Adjust
limit switch actuation point and check operation.
• Limit switch failure. Manually move worktable until limit
switch is clear of limit switch trip ramp. Adjust limit switch
actuation.
Excessive
ballscrew noise
Low or no lubrication.
• Pull out lever on one-shot lubrication system to lube
• ballscrews.
• Check lube level in lube reservoir. Replenish as required.
Worn ballscrew or ball nut.
• Replace ballscrew and ball nutassembly.
Drive motor
inoperative
Fuse blown.
• Replace fuse.
Open windings in motor
• Check for open motor windings. Replace motor if open
Frequency
motor inoperative
Fuse blown.
• Replace fuse.
Open windings in motor.
• Check for open motor windings. Replace motor if open.
Inverter failure/
programming error.
• Refer to Inverter documentation for
• the troubleshooting.
No or low
coolant flow.
Low coolant sump level.
• Check coolant level. Replenish
• coolant as required.
Failed coolant pump.
• Check pump for motor failure.
• Replace if motor failed.
Screens in trough of
machine baseclogged with
chips and machining debris.
• Remove material from screens.
Sludge or debris in inlet of
coolant
pump.
• Clean coolant sump to remove
• pump blockage.
Summary of Contents for HU 320 UM TOPLINE
Page 1: ...HU 320 UM TOPLINE M I L L I N G M A C H I N E...
Page 7: ...7 CHANGES AND TYPING ERRORS RESERVED 3 6 Overall dimentions 1 8 Overall Dimensions 9...
Page 10: ...10 CHANGES AND TYPING ERRORS RESERVED 13...
Page 56: ...56 CHANGES AND TYPING ERRORS RESERVED 6 28 Operate Panel Assembly Operate Panel Assembly 30...
Page 60: ...60 CHANGES AND TYPING ERRORS RESERVED 6 30 Wire Diagram Wire Diagram 34...
Page 61: ...61 CHANGES AND TYPING ERRORS RESERVED...
Page 64: ...2017 V1...