99-16105-S001_A
5/20/2010
Instuctions
DOOR REMOVAL & REVERSAL
Removing the Door Assembly From the 101X Frame
1.
Using a flat-head screwdriver, loosen the tension on the door by turning the adjustment screw, located on the
front of the torquemaster, to the right or clockwise.
Refer to figure
(A)
2.
Test the door by opening it, and confirm that the torque tension does not retract the door from open position.
3.
If tension remains, continue adjusting the torquemaster until all tension has been removed from the door.
4.
Open the door to access the hold open device then loosen and remove hold-open bolt, using a phillips-head
screwdriver.
Refer to figure
(B)
5.
Remove the hold open stud using a 7/16” hand wrench.
6.
Retract the door to a near-closed position.
7.
Insert the top half of the needle-nose pliers into the grip-hole, located in the hinge pin spring-clip, and the bottom
half of the pliers beneath the hinge pin shroud.
Refer to figure
(C)
8.
Squeeze the pliers to clamp down on the hinge pin spring clip, allowing the clip to release the hinge pin from the
receptacle gib of the frame, while simultaneously pulling the top of the door away from the frame. This will release
and pull the hinge pin out of the hinge pin receptacle and gib.
Refer to figure
(D)
12
A
B
C
D
Summary of Contents for HGM-1 BS
Page 2: ......
Page 4: ......
Page 70: ...Hussmann Corporation 12999 St Charles Rock Road Bridgeton MO 63044 2483 www hussmann com...