Fault and Action Table
Mobile bain marie
SPA/K-2DW | SPA/K-3DW
4330036_A1
Fault
Possible cause
Action
Formation of bloom and ice on the
walls of the cooling well,
reduced cooling power
Introduction of too warm, uncovered
or too moist food
Disconnect the appliance from the
power supply and clean the walls of
the well with warm water.
Coolant spills
Ambient air too warm
The ambient temperatures must be
between 50 and 89.6 °F (+10 and
+32 °C).
Defective cooling conduit
Switch off the appliance and call a
technician