INSTALLATION
7
Mount the Installation Brackets — Outside Mount
To attach the end brackets, a flat vertical surface of at least 1
3
⁄
4
" is required for 1
3
⁄
8
", 2", and
2
1
⁄
2
" slat sizes.
Mark the End Bracket Locations
■
■
Mark where the ends of the headrail will be located.
■
➤
Center the headrail over the window opening at the desired height.
Use a pencil to lightly mark each end of the headrail.
■
➤
Alternatively, measure the width of the headrail and use that
width to mark the headrail end points over the window opening.
■
■
Make a second mark
1
⁄
4
" to the outside of the headrail
end marks. The outer marks are where the outside
edges of the end brackets will be located.
Attach the End Brackets
NOTE:
The illustrations in this section show spacer blocks mounted with the end brackets
for 1
3
⁄
8
", 2", and 2
1
⁄
2
" slat sizes. Spacer blocks are required for all outside mount 2
1
⁄
2
" blinds,
unless extension brackets are used. Spacer blocks are optional for 1
3
⁄
8
" and 2" slat sizes.
■
■
Align the outside edge of each end bracket with the outer marks and mark diagonal screw
holes.
■
➤
Use a
3
⁄
32
" drill bit to drill holes for the mounting screws.
Mark
Measure and Mark
1
∕
4
"
Out from
Ends of Headrail
Mark