6.6 Firmware update
Pull-down menu: Options
Firmware update
6.6.1 Module firmware update
The modules are prepared for a firmware update by pressing the button on the front plate of the
UO-SCU during the switch on process.
Press the button to select the update file.
“Transfer” starts the update process.
The device must be restarted after the update
process.
6.6.2 Basic device firmware update
The basic device is prepared for a firmware update
by connecting the USB port in the junction bow to
the PC during the switch on process.
Press the button to select the update file.
“Transfer” starts the update process.
The device must be restarted after the update process.
6.7 Reset to default settings
Pull-down menu: Options
Reset to default settings
The configuration is deleted and the modules are reset to default settings
Default settings:
Password Level1
Password Level2
huebner1
huebner2
Operating mode
Position speed
mode
Reset and preset
inputs
deactivated
Speed and position
switch points
deleted
Error reset only with
software
active
Test pulse duration
1 ms
T/ti
1000
Current output
deactivated
Current output source
position-
dependent
Incremental output
(optional)
4096
pulses/revolution
Fig. 6-4: Firmware update